GNGTS 2014 - Atti del 33° Convegno Nazionale

436 GNGTS 2014 S essione 2.3 Idriss I. M. and Boulanger R. W. (2008): Soil liquefaction during earthquake , Earthquake Engineering Research Institue, EERI Publication MNO-12; Iwasaki T., Tatsuoka F., Tokida K. and Yasuda S. (1978): A pratical method for assessing soil liquefaction potential based on case studies at various sites in Japan , 3 rd International conference on microzonation, San Francisco, pp. 885-896. Lo Presti D., Meisina C and Squeglia N. (2009): Applicabilità di prove penetrometriche statiche nella ricostruzione del profilo stratigrafico , Rivista Italiana di Geotecnica, vol. 2, pp. 9-33. Massa M., Augliera P., Carannante S., Cattaneo M., D’Alema E., Lovati S., Monachesi G., Moretti M. and Piccinini D. (Seismological projects DPC-INGV 2012-2013): May-June 2012 Emilia seismic sequence: relocated seismicity , Project S1, Base-knowledge improvement for assessing the seismogenic potential of Italy, Deliv������ ���� ���� erable D18, Task b2, https://sites.google.com/site/ingvdpcprojects1/home. Martelli L. and Romani M. (2013): Microzonazione Sismica e analisi della Condizione Limite per l’Emergenza delle aree epicentrali dei terremoti della pianura emiliana di maggio-giugno 2012 (Ordinanza del Commissario Delegato – Presidente della Regione Emilia-Romagna n. 70/2012) - Relazione illustrativa , http://mappegis. regione.emilia-romagna.it/gstatico/documenti/ord70_20121113/MSord70_relazione.pdf. Meletti C. and Valensise G. (2004): Zonazione sismogenetica ZS9 – App.2 al Rapporto Conclusivo, In: Gruppo di Lavoro MPS (2004). ��������� ����� ����� �� ������������ ������� �������� �������������� ��� ���� ��� �� Redazione della mappa di pericolosità sismica prevista dall’Ordinanza PCM 3274 del 20 marzo 2003. Rapporto Conclusivo per il Dipartimento della Protezione Civile, INGV, Milano-Roma, aprile 2004, 65 pp. � � ��������� + 5 allegati. NTC (2008): Approvazione delle nuove norme tecniche per le costruzioni . Decreto del Ministero delle infrastrutture 14 gennaio 2008. (Pubblicato nella G.U. n° 29 del 04/02/2008 - suppl. ord. n° 30) Ordinanza n. 70 del 13/11/2012 del presidente Errani in qualità di Commissario delegato: Approvazione programma per gli studi di microzonazione sismica . (Registrata alla Corte dei Conti Sezione Regionale di Controllo per l’Emilia-Romagna, in data 21 novembre 2012 registro n. 1, foglio n. 381). http://www.regione.emilia-romagna.it/ terremoto/gli-atti-per-la-ricostruzione/ordinanze-del-presidente-errani-in-qualita-di-commissario-delegato-2012 Papathanassiou G., Caputo R. e Rapti-Caputo D. (2012): “ Liquefaction-induced ground effects triggered by the 20th May, 2012 Emilia-Romagna (Northern Italy) earthquake ”. ������ �� ��������� Annals of Geophys., 55 (4), doi: 10.4401/ag-6147. Pieri M. and Groppi G. (1981): Subsurface geological structure of the Po Plain, Italy . Consiglio Nazionale delle Ricerche, Progetto finalizzato Geodinamica, sottoprogetto Modello Strutturale, pubbl. N° 414, Roma, 13 pp. Preliminary seismic vulnerability assessment of a steel oil storage tank: geophysical analysis and design spectra definition G. Massolino 1 , C. Barnaba 1 , S. Forchiassin 2 , R. Romeo 1 , D. Sandron 1 , M. Santulin 1 , A. Tamaro 1 1 OGS - Istituto Nazionale di Oceanografia e di Geofisica Sperimentale, Trieste-Udine, Italy 2 SIOT - Società Italiana per l’Oleodotto Transalpino, Trieste, Italy Introduction. It is well known earthquakes induce sloshing in tanks caused by long-period ground motion (Housner, 1963; Hanson, 1964; Manos and Clough, 1985). This aspect was dramatically emphasized in Japan, after the 2003 Tokachi-oki earthquake (M=8.0) occurred on 26 September, east of Hokkaido, north of Japan, when the oil storage tanks in Idmitsu Rafinery suffered severe damage (Zama, 2004). Natural period of sloshing depends on the diameter of tank and the liquid height, and it is trigged by the power of seismic ground motion. Due to the slow attenuation of the long-period ground motion, a minimum freeboard is needed to accommodate the sloshing waves and to avoid oil leaks. In this paper, it is presented a case study of a 10000 m 3 hydrocarbon buffer storage tank, belonging to the pipeline system owned by the Società Italiana Oleodotto Transalpino (SIOT), part of the TAL group (Transalpine Pipeline), built in the 1960s in the NE Italy. This analysis is part of a study project funded by the European Social Fund, within the SHARM (Support Human Asset and Research Mobility) educational program. The study area, is close to the epicenter of the 1976 (M=6.4) Friuli earthquake and it was stuck in the past by several earthquakes of M>5.5 (Bressan et al. , 2003).

RkJQdWJsaXNoZXIy MjQ4NzI=